Home /

Cast Iron Hot Gas Solenoid Valve / EVR20 Liquid Solenoid Valve For Refrigeration

Send your message to this supplier
*From:
Your email address is incorrect!
To:Ningbo Brando Hardware Co., Ltd
*Subject:
Your subject must be between 10-255 characters!
*Message:
Your message must be between 20-3,000 characters!
Yes!I would like your verified suppliers matching service!
Buy cheap Cast Iron Hot Gas Solenoid Valve / EVR20 Liquid Solenoid Valve For Refrigeration from wholesalers
  • Buy cheap Cast Iron Hot Gas Solenoid Valve / EVR20 Liquid Solenoid Valve For Refrigeration from wholesalers
  • Buy cheap Cast Iron Hot Gas Solenoid Valve / EVR20 Liquid Solenoid Valve For Refrigeration from wholesalers
  • Buy cheap Cast Iron Hot Gas Solenoid Valve / EVR20 Liquid Solenoid Valve For Refrigeration from wholesalers
  • Buy cheap Cast Iron Hot Gas Solenoid Valve / EVR20 Liquid Solenoid Valve For Refrigeration from wholesalers

Cast Iron Hot Gas Solenoid Valve / EVR20 Liquid Solenoid Valve For Refrigeration

Ask Latest Price
Brand Name:Brando
Model Number:EVR20
Certification:CE
Price:negotiation
Payment Terms:L/C, T/T, Western Union,Paypal
Supply Ability:4400 sets per month
Delivery Time:4-8 days
Company Data
Verified Supplier
Contact Person Brandon Bao
Business Type: Manufacturer Distributor/Wholesaler Exporter Seller
Officials: 608, Building B, Yinyi Duhui Guoji, No.8, Lane 559, Youngor Avenue, Haishu District, Ningbo, China
Quality: Quality Certifitation Available
Visit Website
Product Details Company Profile
Product Details

EVR20 Refrigeration Solenoid Valves -40°C-105°C HCFC/HFC/CFC Brass Natural Color


EVR20 Refrigeration Solenoid Valves are connected to a series of refrigerating system ducts and are controlled by a command signal from a pressure relay, relay, temperature level controller and manual switch to open and close system fluid ducts, and are commonly used for refrigeration. System pipes open and close automatically with system control commands. When connected to the controller, it can cut off the flow of fluid in the system.


Technical data:

Models:Port sizeH1H2H4LL2KV(m³/h)
SAE Inlet/OutletODF Inlet/OutletInchmmInchmmInchmmInchmmInchmmInchmm
EVR3-014EVR3-014S1/460.5142.8714.01020.370.27
EVR3-038EVR3-038S3/8100.5142.9734.61170.410
EVR6-038EVR6-038S3/8100.5143.1794.41110.4100.8
EVR6-012EVR6-012S1/212.80.5143.1795.01270.410
EVR10-012EVR10-012S1/212.80.6163.1795.01270.4101.9
EVR10-058EVR10-058S5/8160.6163.1796.31600.512
EVR15-058S5/8160.7193.4866.91760.5122.6
EVR15-078S7/8220.7193.4866.91760.717
EVR20-078S7/8220.8203.5907.51910.7175
EVR20-118S1 1/828.80.8203.5908.42140.822
EVR22-138S1 3/8350.8203.59011.12811256
EVR25-118S1 1/828.81.5385.41382.87210.02560.82210
EVR25-138S1 3/8351.5385.41382.87211.0281125
EVR32-138S1 3/8351.9474.41112.15311.028112516
EVR32-158S1 5/8421.9474.41112.15311.02811.129
EVR40-158S1 5/8421.9474.41112.15311.02811.12925
EVR40-218S2 1/8541.9474.41112.15311.02811.334

Main dimension of EVR20 Refrigeration Solenoid Valves:

Cast Iron Hot Gas Solenoid Valve / EVR20 Liquid Solenoid Valve For Refrigeration


EVR20 Refrigeration Solenoid Valve be used in Refrigeration Unit:

Cast Iron Hot Gas Solenoid Valve / EVR20 Liquid Solenoid Valve For Refrigeration


Application fleid of EVR20 Refrigeration Solenoid Valve:

Cast Iron Hot Gas Solenoid Valve / EVR20 Liquid Solenoid Valve For Refrigeration


Function of EVR20 refrigeration solenoid valve in refrigeration system:

EVR20 Refrigeration Solenoid Valve can be used in evaporator liquid supply lines. When the compressor is shut down, the liquid can be closed into the evaporator to prevent the wet steam from entering the evaporator when the compressor is shut down. The compressor produces the liquid hammer. Another example is the cooling water pipe used by the condenser, which automatically cuts off or opens the water source while the compressor is turned on and off to save cooling water. In addition, the solenoid valve can also be used as a pilot valve to control the main valve and other applications. In short, it is combined with some automatic electrical appliances, constitute the refrigeration system automatic control and regulation of the main components.


Cold storage EVR refrigeration solenoid valve selection, installation and inspection considerations:

The working current, voltage, frequency and power of each solenoid coil have a certain range, which cannot be abused to avoid burning out. As the voltage drops, so does the coil's suction. When the ac frequency is low, the suction increases, but the coil is hot, easy to burn out. When assembling the solenoid valve, the coil part should be assembled correctly according to the drawings in the manual to avoid increasing the magnetoresistor. The increase of magnetoresistance will not only reduce the electromagnetic suction, but sometimes the direction of the suction is not correct, affecting the valve action.


Different duty stations should use different types of electromagnetic widths. For example, solenoid valves in refrigerant lines should not be used in water pipes because water can scale, solid impurities are difficult to avoid and can easily clog small balance holes in the diaphragm. For the solenoid valve on the oil separator return pipe, shockproof measures should be taken to avoid the compressor exhaust pressure fluctuation to open and close the auxiliary valve. For use with suction solenoid valves, use hygroscopic coils or close solenoid valves as they are prone to condensation. Should be used when the environment temperature is higher than 40 ℃, hot coil, etc.


Solenoid valve must coil, vertical installation in the pipeline, otherwise, because the core can not work properly and failure. Solenoid valve media flow from the top of the spool to the bottom, so must be in accordance with the direction of the arrow marked on the valve body installation, arrow direction for the flow of pipeline media.


In order to check whether the solenoid valve works normally, a light bulb can be connected in parallel on the power line of the solenoid valve to indicate its switching state. Manual switch is also available in series on the power line of the solenoid valve. When the circuit and manual switch on and off, if you can hear the sound of the solenoid valve spool action, the solenoid valve is working normally. The abnormal operation of solenoid valve mainly occurs in three aspects: coil burning, spool sticking and iron core remanence. The core can be removed and removed by heating or tapping if the core residues do not allow the power to drop automatically.


Welcome to your inquiry!

Company Profile

Ningbo Brando Hardware Co., Ltd

* Foucus on your demand, Offer you best solutions as the first mission of Ningbo Brando Hardware Co., Ltd, we work on designing and manufacturing solenoid coils, solenoid armatures and solenoid valves for more than 15 years.

 

* We have served customers from Europe, North America, Middle east, Southeast Asian by designing and manufacturing for their automation fluid control applications, related to industries of pneumatic automation equipment, food beverage dispenser, agricultural irrigation, printing and dyeing, dust collector, home appliance, automobile, textile, refrigeration, etc.

 

Since the company's inception, we are dedicated to providing high quality products and service to our customers. With focusing on our customers' demands, at before production we discuss technical points according to applications with customers to reduce mistake and save cost for both sides. During production, we use high precision CNC machine, machining center to control dimensions and improve productivity. At beginning and mid of machining, our senior inspectors check quality regularly by recording data on documents as per ISO9001 management system. Before shipment, our staff make testing and complete inspection one piece by one piece to ensure the products without defect when reached our customer's hands.

 

Ningbo Brando Hardware Co., Ltd will offer you best service with fast response, let's make the fluid control application more widely and smartly.

 

 

Product Categories:

1. Solenoid Valve
2. Solenoid Coil
3. Solenoid Armature
4. Solenoid Coil Connector
5. Solenoid Valve Timer
6. Pulse Valve
7. Valve Diaphragm
8. Pulse Controller
9. Refrigeration Valve
10. Pneumatic Valve
11. Pneumatic Fitting
12. Pneumatic Cylinder
13. Pneumatic Filter Regulator Lubricator
14. Pneumatic Vibrator
15. Ball Valve
16. Butterfly Valve
15. and so on

Send your message to this supplier
*From:
Your email address is incorrect!
*To:

Ningbo Brando Hardware Co., Ltd

*Subject:
Your subject must be between 10-255 characters!
*Message:
Your message must be between 20-3,000 characters!
Characters Remaining : (0/3000)

You May Like

China EVR 3 220/230V AC Refrigeration Solenoid Valve with Brass Body , Liquid Line Solenoid Valve wholesale

EVR 3 220/230V AC Refrigeration Solenoid Valve with Brass Body , Liquid Line Solenoid Valve

China Direct Operated EVR6-038S Hot Gas Solenoid Valve Applicable for Freezer And Cold Store And Air Conditioning wholesale

Direct Operated EVR6-038S Hot Gas Solenoid Valve Applicable for Freezer And Cold Store And Air Conditioning

China Normally Closed EVR Refrigeration Solenoid Valve Air Conditioning , Solenoid Operated Valve wholesale

Normally Closed EVR Refrigeration Solenoid Valve Air Conditioning , Solenoid Operated Valve

China 018F6701 Solenoid With Brass Body Copper Pipe Refrigeration Solenoid Valve for Fluorinated Gas Lines wholesale

018F6701 Solenoid With Brass Body Copper Pipe Refrigeration Solenoid Valve for Fluorinated Gas Lines

China Danfoss Type EVR 40 NC Refrigeration Solenoid Valve 1 5/8'' 2 1/8'' wholesale

Danfoss Type EVR 40 NC Refrigeration Solenoid Valve 1 5/8'' 2 1/8''

China Danfoss Type Solenoid Valve EVR 32 042H1104 042H1106 042H1108 wholesale

Danfoss Type Solenoid Valve EVR 32 042H1104 042H1106 042H1108

China Medium Pressure Normally Closed Solenoid Valve / DC12V Liquid Line Solenoid Valve wholesale

Medium Pressure Normally Closed Solenoid Valve / DC12V Liquid Line Solenoid Valve

China Danfoss Type Solenoid Valve EVR 40 042H1110 042H1112 042H1114 wholesale

Danfoss Type Solenoid Valve EVR 40 042H1110 042H1112 042H1114

China Sporlan Type Hot Gas Bypass Valve ADRIE-1-1/4 ADRSE-2 ADRPE-3 ADRHE-6 wholesale

Sporlan Type Hot Gas Bypass Valve ADRIE-1-1/4 ADRSE-2 ADRPE-3 ADRHE-6

China Danfoss Type EVR 32 NC Refrigeration Solenoid Valve 1 3/8'' 1 5/8'' wholesale

Danfoss Type EVR 32 NC Refrigeration Solenoid Valve 1 3/8'' 1 5/8''

China EVR10-012S Brass Refrigeration Solenoid Valve Control Refrigerant Flow wholesale

EVR10-012S Brass Refrigeration Solenoid Valve Control Refrigerant Flow

Inquiry Cart 0